Integration of inertial sensors into the OpenSim software for human movement assessment

Authors

DOI:

https://doi.org/10.59681/2175-4411.v18.iEspecial.2026.1819

Keywords:

Digital Health, IMU, Motion Capture

Abstract

Objective: To present a methodological proposal for integrating inertial sensor data into OpenSim, emphasizing calibration, data collection, processing, and kinematic motion representation. Method: The workflow included accelerometer calibration, data acquisition, signal filtering, estimation of knee flexion/extension angle, and data structuring in a format compatible with OpenSim. Results: Calibration reduced the root mean square error of the measurements, indicating improved signal consistency. The experimental data were converted and integrated into a musculoskeletal model, enabling visualization of the analyzed movement. Conclusion: The proposed methodology proved applicable to the preliminary integration of IMUs with OpenSim. Although restricted to knee movement, it has potential for expansion to multiple body segments after complete system validation.

Downloads

Download data is not yet available.

Author Biographies

Davi Ismael Costa Damacena, PPGEB-UnB, Brasília (DF), Brasil

PPGEB-UnB, Brasília (DF), Brasil.

Claudia Patricia Ochoa-Diaz, FCTE-UnB, Brasília (DF), Brasil

FCTE-UnB, Brasília (DF), Brasil.

Jorge Andrés Cormane Angarita, PPGEB-UnB, Brasília (DF), Brasil

PPGEB-UnB, Brasília (DF), Brasil.

References

1. Porciuncula F, Roto AV, Kumar D, Davis I, Roy S, Walsh CJ, et al. Wearable Movement Sensors for Rehabilitation: A Focused Review of Technological and Clinical Advances. PM R. 2018;10(9 Suppl 2):S220-S232. doi: https://doi.org/10.1016/j.pmrj.2018.06.013

2. Picerno P, Iosa M, D'Souza C, Benedetti MG, Paolucci S, Morone G. Wearable inertial sensors for human movement analysis: a five-year update. Expert Rev Med Devices. 2021;18(sup1):79-94. doi: https://doi.org/10.1080/17434440.2021.1988849

3. Bonato P, Feipel V, Corniani G, Arin-Bal G, Leardini A. Position paper on how technology for human motion analysis and relevant clinical applications have evolved over the past decades: Striking a balance between accuracy and convenience. Gait Posture. 2024;113:191-203. doi: https://doi.org/10.1016/j.gaitpost.2024.06.007

4. Hindle BR, Keogh JWL, Lorimer AV. Inertial-Based Human Motion Capture: A Technical Summary of Current Processing Methodologies for Spatiotemporal and Kinematic Measures. Appl Bionics Biomech. 2021;2021:6628320. doi: https://doi.org/10.1155/2021/6628320

5. García-de-Villa S, Casillas-Pérez D, Jiménez-Martín A, García-Domínguez JJ. Inertial Sensors for Human Motion Analysis: A Comprehensive Review. IEEE Trans. Instrum. Meas. 2023;72:1-39. doi: https://doi.org/10.1109/tim.2023.3276528

6. Wechsler I, Wolf A, Fleischmann S, Waibel J, Molz C, Scherb D, et al. Method for Using IMU-Based Experimental Motion Data in BVH Format for Musculoskeletal Simulations via OpenSim. Sensors (Basel). 2023;23(12):5423. doi: https://doi.org/10.3390/s23125423

7. Damacena DIC, Silva DS, Monte ECDS, Paz CCSC, Cormane J, Diaz CO. Desenvolvimento de um sistema de medição da trajetória do centro de massa corporal baseado em sensores inerciais. In: Anais do XVI Simpósio de Engenharia Biomédica; 2025 set 15-17; Uberlândia, MG, Brasil. Zenodo; 2025. doi:10.5281/zenodo.17363496.

8. OpenSim. Musculoskeletal models [Internet]. Stanford: OpenSim; [cited 2026 Mar]. Available from: https://opensimconfluence.atlassian.net/wiki/spaces/OpenSim/pages/53090607/Musculoskeletal+Models

9. Krishna RCA, Mukherjee B, Bhalla S, S S. Static and Dynamic Calibration of 9-Axis IMU Using UKF with Low Cost Setup. In: 2024 IEEE 21st India Council International Conference (INDICON). [s.l.]: IEEE; 2024. p. 1-6. doi: https://doi.org/10.1109/indicon63790.2024.10958268

10. Al Borno M, O'Day J, Ibarra V, Dunne J, Seth A, Habib A, et al. OpenSense: An open-source toolbox for inertial-measurement-unit-based measurement of lower extremity kinematics over long durations. J Neuroeng Rehabil. 2022;19(1):22. doi: https://doi.org/10.1186/s12984-022-01001-x

Published

2026-11-26

How to Cite

Damacena, D. I. C., Ochoa-Diaz, C. P., & Cormane Angarita, J. A. (2026). Integration of inertial sensors into the OpenSim software for human movement assessment. Journal of Health Informatics, 18(Especial), 1819. https://doi.org/10.59681/2175-4411.v18.iEspecial.2026.1819