Shape Analysis 3D to false positive reduction
Palavras-chave:
False positive reactions, Anatomy regional, Lung neoplasmsResumo
Objective: The present work describes the development of a methodology for the reduction of false positives, so that it helps in the consistent distinction between pulmonary nodules and other structures present in CT examinations. Methods: The proposed method is based on the exploration of characteristics of form related to compactness, spherical disproportion, Feret diameters, skeleton and statistical measures. These characteristics were submitted to a set of classifiers, highlighting the MLP algorithm. The method was evaluated in a set of 24156 regions from 833 examinations of the LIDC-IDRI base. Results: The method was promising, reaching 91% of sensitivity, 92.8% of specificity and 92.3% of accuracy. Conclusion: The results showed that the morphological analysis is satisfactory and presents significant contributions to the CAD systems, directly aiding in a more favorable prognosis to the patient.Downloads
Publicado
Como Citar
Edição
Seção
Licença
A submissão de um artigo ao Journal of Health Informatics é entendida como exclusiva e que não está sendo considerada para publicação em outra revista. A permissão dos autores para a publicação de seu artigo no J. Health Inform. implica na exclusiva autorização concedida aos editores para incluí-lo na revista. Ao submeter um artigo, ao autor será solicitada a permissão eletrônica de um Termo de Transferência de Direitos Autorais. Uma mensagem eletrônica será enviada ao autor correspondente confirmando o recibo do manuscrito e o aceite da Declaração de Direito Autoral.